Quality Control Laboratory
Testing Laboratory & Quality Assurance
Independent quality lab with ISO 9001 processes — every unit tested before shipment
Aquafarer operates a dedicated quality control laboratory that operates independently from production. Every batch of raw material and every finished boat passes through documented inspection protocols before release. Our QC team reports directly to management, ensuring impartial quality decisions.
Test Procedures
Quality Testing Procedures
Raw Material Inspection
Every incoming batch of PVC, Hypalon, drop-stitch fabric, and hardware is tested before acceptance. Tensile strength (ASTM D751), tear resistance (ISO 4674), and UV resistance are verified. Non-conforming materials are quarantined and returned.
ASTM D751 (tensile), ISO 4674 (tear), ISO 4892 (UV)
In-Process QC Checkpoints
Production operators perform self-inspection at each stage. QC auditors conduct random sampling throughout the shift. Weld peel tests are performed every 50 units. Dimensional checks happen every 20th panel.
ASTM D751 (peel), Internal 100-point checklist, ISO 2859 sampling
48-Hour Air Retention Test
Every tube chamber is inflated to 125% of rated pressure and held for 48 hours. Pressure sensors log continuously with temperature compensation. Any chamber exceeding 5% pressure drop triggers automatic batch re-inspection.
ISO 6185, CE 2013/53/EU
Load & Balance Testing
Completed boats are tested at maximum rated capacity for stability, freeboard, and handling. Each vessel undergoes water testing before final inspection approval.
ISO 12217, CE 2013/53/EU
Lab Equipment
Testing Equipment
Need quality documentation?
Request our QC manual, test reports, or factory audit documentation.
Request documentation →